E-003 Overhead Ionizing Air Blower is a device of the ionizing air blower series. The E-003 blower is an overhead unit designed to provide total coverage for electrostatic problems.
Please read the instruction manual completely before installing or operating the device. This device is equipped with a 3-wires grounding plug and must be plugged into a 3-terminal grounded socket. Do not modifying plug or using an ungrounded power socket. If an extension cord is required, it should be used only a 3-wire extension cord with grounding.
Do not insert any object through intake or outlet grille.
Do not operate the unit under inflammable or explosive atmospheres.
Internal repairs or servicing should be done by SL-003 technician.
SPECIFICATION
Line Voltage 220VAC/ 50 Hz or 110VAC / 60Hz
Current Consumption Max.1.25 Amp (fan high, light on)
Min.0.62 Amp (fan low, light off)
Air Volume Output Fan speed Flow
Low 120 CFM
High 330 CFM
(Flow amount equal to sum of 3 fans)
Air Flow Characteristics 40cm×120cm Area Coverage
Light Output 1650 Lumens Total.
Replacement Lamp 13-15 Watt Energy Saving Fluorescent
Operating Temperature 32ºF(0℃)~122ºF(50℃)
Enclosure Stainless Steel
Finish Powder Coat
Size 1100mm(L)×184mm(W)×110mm(H)
Optional Air Filter 30PPl Open Polyurethane Foam
Ion Balance(offset voltage) 0V+/-10V(It requires no calibration)
Testing Result(for reference only)
Away from Blower |
Left 300mm |
Center line |
Right 300mm |
300mm |
1.8sec |
1.3sec |
1.7sce |
600mm |
2.5sec |
2.2sec |
2.3sec |
900mm |
5.2sec |
4.3sec |
4.8sec |
1200mm |
8.6sec |
7.5sec |
8.3sec |
1. Ion balance and decay time is according to the ESD standard, the neutralizing static time is in the voltage of 1000V-100V.
2. Test data available using ME268A chargers plate analyzer.
3. Test figures are subject to the variation in the atmospheric conditions.
Payment Terms︰ TT