Product Description

The SL-090 ion wind drum can generate a large amount of airflow with positive and negative charges, which can neutralize the charge on the object. When the charge on the surface of the object is negative, it will attract the positive charge in the airflow. When the charge on the surface of the object is positive, it will attract the negative charge in the airflow, so that the static electricity on the surface of the object is neutralized. , To achieve the purpose of eliminating static electricity.

The SL-090 ion wind drum is provided by a multi-blade centrifugal fan. The wind power can be adjusted in a large range by using a high-power speed regulator and frequency converter.

The ion wind drum forms a stable high-voltage electric field, and ionizes the air to form an ion body, which is carried by the airflow to the surface of the object, achieving the purpose of neutralizing static electricity.

Section 2 Product Features

1. The air output is large and the static electricity is neutralized quickly.

2. Using multi-wing centrifugal fan, the blown out ion airflow is strong and covers a wider area.

3. Wide adjustment range of wind power (high-power speed regulator and frequency converter can be selected separately).

4. The wind drum has good grounding protection.

Section 3 Technical Parameters

Operating voltage: AC 220V /380V

Power consumption: 510VA

Air output: 335~410CFM

Operating temperature: -10℃~45℃

Ozone concentration: 0.03PPM (the wind speed is adjusted to the minimum, measured 6 inches before the wind drum)

Drum box material: iron alloy

Weight: 17.5kg

Dimensions: 500(L)×240(W)×370(H)mm

Ion balance: -50V~+50V

In addition to static time:

Test conditions Test voltage: 5000V~500V; -5000V~-500V

Ambient temperature: 22℃±5℃ Relative humidity: ≤60%

Distance 300mm

Static elimination time positive ≤0.9S

burden

Residual voltage -50V~+50V

*The test method is based on: IEC61340-5-1.

*The test data is subject to the test result of the ME268A electrostatic comprehensive tester.

*The test data will be different due to changes in the temperature and humidity of the surrounding air.